
·9 min read
Architect Specification Guide for PONARC Aluminium Systems.
Specification writing guide for architects. CSI MasterFormat, performance criteria, profile reference details and technical reference objects for PONARC systems.
CSI MasterFormat Specification\n\nPONARC aluminium systems are specified under MasterFormat Division 10 (Specialties) Section 10 73 00 (Protective Covers) for pergola and canopy systems, and Division 05 (Metals) Section 05 73 00 (Decorative Metal Railings) for glass railing systems. The three-part specification format includes Part 1: General (scope, references, submittals, quality assurance), Part 2: Products (materials, fabrication, finishes), and Part 3: Execution (installation, adjustment, cleaning). PONARC provides pre-written specification sections that architects can adapt for project-specific requirements.\n\n## Performance Specification Criteria\n\nPerformance-based specifications define required outcomes rather than prescriptive material selections. Key performance criteria include: wind load resistance (specify design wind pressure in kN/m2 per EN 1991-1-4), snow load capacity (specify characteristic snow load per EN 1991-1-3), thermal performance (specify maximum U-value for glazed elements), acoustic performance (specify minimum Rw rating), and fire classification (specify minimum EN 13501-1 rating). PONARC systems meet or exceed standard performance requirements for European installations.\n\n## profile reference Detail Library\n\nPONARC provides a comprehensive profile reference detail library for integration into architectural drawings. Standard details include foundation connections (pad, strip, and pile options), wall interface details (face-fix, concealed bracket, and cantilever options), drainage integration (internal gutter, external gutter, and chain drainage), electrical routing (concealed cable paths for motors, lighting, and sensors), and glass railing base channel sections. All details are available in project-reference and PDF formats.\n\n## technical reference Object Library\n\nsystem data families are available for all PONARC product ranges at LOD 300 (design development) and LOD 400 (construction documentation) detail levels. Project reference packs focus on dimensions, material notes and manufacturer data. The technical reference library is updated quarterly to reflect current product specifications and new product releases.
Project checks before specification
For a reliable LuxaShade proposal, match the article topic with the real site conditions before selecting a product family.
- Confirm span, fixing surface, drainage route and wind exposure for the installation area.
- Compare pergola, zip screen, veranda, carport and railing options against the same opening dimensions.
- Share photos, rough measurements and preferred colour so the dealer can route the request to the right system.
Use the product pages for system details, then contact LuxaShade for a project-specific review.
Explore our product range or get in touch.


